Alumina Thermal Analyzer Crucibles (Al2O3 Thermal Analyzer Crucibles) | TAC-0
Item Number: TAC-0. Alumina Thermal Analyzer Crucibles (Al2O3 Thermal Analyzer Crucibles) can be used in following equipment: DSC, TA, PerkinElmer, Mettler, Netzsch, TGA, Linseis, DuPont, Setaram, Rigaku, Setaram, SII, Bruker AXS, Shimadzu etc.
Alumina Thermal Analyzer Crucibles (Al2O3 Thermal Analyzer Crucibles): Precision and Reliability for Thermal Analysis
Alumina Thermal Analyzer Crucibles (Al2O3 Thermal Analyzer Crucibles) can be used in a variety of equipment, including DSC, TA, PerkinElmer, Mettler, Netzsch, TGA, Linseis, DuPont, Setaram, Rigaku, SII, Bruker AXS, Shimadzu, etc.
Thermal Analyzer Crucibles (Sample pan) List:
All 100pcs/1pkg.
Product Specifications
| Item No. | D (mm) | H (mm) | Wall (mm) | Capacity | Instrument |
|---|---|---|---|---|---|
| TAC-001 | 6 | 2.6 | 0.45 | 30ul | Mettler Toledo/Shimadzu |
| TAC-002 | 6 | 4.5 | 0.45 | 70ul | Mettler Toledo |
| TAC-003 | 6.5 | 5 | 0.5 | 85ul | Mettler Toledo |
| TAC-004 | 8 | 4.5 | 0.5 | 150ul | Mettler Toledo |
| TAC-005 | 12 | 10 | 1 | 900ul | Mettler Toledo |
| TAC-006 | 7.5 | 1.8 | 0.4 | 25ul | Netzsch |
| TAC-007 | 7 | 2 | 0.5 | 25ul | Netzsch |
| TAC-008 | 6.7 | 5 | 0.45 | 80ul | Netzsch |
| TAC-009 | 6.8 | 4 | 0.5 | 80ul | Netzsch |
| TAC-010 | 6.4 | 8 | 0.5 | 160ul | Netzsch |
| TAC-011 | 8 | 8 | 0.6 | 160ul | Netzsch |
| TAC-012 | 8 | 23 | 0.8 | 550ul | Netzsch DTA |
| TAC-013 | 18 | 8 | 0.9 | 1mL | Netzsch |
| TAC-014 | 17 | 30 | 0.5 | 3.0ml | Netzsch |
| TAC-015 | 5 | 3 | 0.4 | 30ul | Setaram |
| TAC-016 | 5 | 4 | 0.45 | 50ul | Setaram |
| TAC-017 | 8 | 3 | 0.6 | 95ul | Setaram |
| TAC-018 | 5 | 8 | 0.45 | 100ul | Setaram DSC |
| TAC-019 | 5 | 10 | 0.45 | 100ul | Setaram |
| TAC-020 | 8 | 6 | 0.45 | 160ul | Setaram |
| TAC-021 | 8 | 12 | 0.5 | 400ul | Setaram |
| TAC-022 | 6.5 | 4 | 0.4 | 75ul | TA SDT Q600 |
| TAC-023 | 4.5 | 7 | 0.6 | 50ul | PerkinElmer/DuPont |
| TAC-024 | 5.2 | 2.5 | 0.35 | 25ul | SII/Bruker AXS |
| TAC-025 | 5.2 | 5 | 0.35 | 65ul | SII/Bruker AXS |
| TAC-026 | 7 | 5 | 0.6 | 95ul | Linseis |
| TAC-027 | 7 | 17.4 | 0.5 | 300ul | Linseis |
| TAC-028 | 17 | 30 | 0.5 | 3.0ml | Linseis |
| TAC-029 | 5 | 5 | 0.5 | 60ul | Rigaku |
Why Choose Our Alumina Thermal Analyzer Crucibles?
- High Purity: Made from high-purity alumina for minimal sample contamination.
- Durable: Exceptional wear and corrosion resistance.
- Precision: Engineered to precise dimensions for compatibility with a wide range of instruments.
- Versatile: Suitable for various thermal analysis applications.
Contact Us
For your thermal analysis needs, trust our Alumina Thermal Analyzer Crucibles to deliver reliable performance. Contact our technical team today to discuss your requirements and place your order.
-
ReferenceTAC-0
-
Item NumberTAC-0
-
FormulaAl2O3
-
Purity99%